Vacuum components   Vacuum components
 
  Home page   Products   About us   Contact info   Site map  
 
   

 

 

 

Protective untriggered gap Ð-74

Metal-ceramic protective untriggered gap P-74 is designed to protect lines of communication and communication equipment from pulse surge and currents.

 

Basic electric parameters of protective untriggered gap Ð-74:

The name of the parameter, unit of measure

Norm

no less than

no more than

Puncture potential, static, V

180

300

Puncture potential, dynamic, kV (with the speed of voltage increase on the electrodes of the surge absorber no more than 4 kV/microsecond)

 

3

Static interelectrode capacitance, picofarad

 

15

Dielectric resistance, Megaohm

500

 

Protective untriggered gap P-74 Protective untriggered gap P-74

 

Instructions on the operation of protective untriggered gap Ð-74 :

  • Metal-ceramic protective untriggered gap P-74 possesses four discharge gaps. The flange is the joint cathode terminal. Four lamels are four anode buttons.
  • Gaps can protect simultaneously four cable conductors with opposite directions of effecting impulse of voltage.
  • Voltage is recommended to supply with the help of flexible conductors.
  • We recommend to joint to the electrodes of the gap with the help of screws using the holes on the anode buttons and the flange.
  • On-position of protective untriggered gap Ð-74 – any position. Cooling down – natural cooling.

Top

 

 

 

 

 

 

 

 

 

 