Protective untriggered gap Ð-63
Protective untriggered gap Ð-63 is designed to protect lines of communication and communication equipment and other radio engineering facilities from pulse surge and currents.
Basic electric parameters of protective untriggered gap Ð-63:
The name of the parameter, unit of measure |
Norm |
no less than |
no more than |
Puncture potential, static, V |
200 |
300 |
Time of disruption lag, microsecond (with the speed of voltage increase on the electrodes of the surge absorber no more than 4 kV/microsecond) |
|
0,5 |
Static interelectrode capacitance, picofarad |
|
10 |
Dielectric resistance, Megaohm |
500 |
|
Instructions on the operation of protective untriggered gap Ð-63:
|
- Ð-77
- Ð-78
- Ð-79
- P-80
- Ð-81, Ð-81-1
- Ð-125, Ð-125-1