Vacuum components   Vacuum components
 
  Home page   Products   About us   Contact info   Site map  
 
   

 

 



Protective untriggered gap Ð-60

Protective untriggered gap Ð-60 is designed to protect equipment from overwork in radio engineering facilities of movable and fixed equipment.

 

Basic electric parameters of protective untriggered gap Ð-60:

The name of the parameter, unit of measure

Norm

no less than

no more than

Puncture potential, static, kV

2,0

3,3

Puncture potential, dynamic, kV (with the speed of voltage increase on the electrodes of the surge absorber no more than 25 kV/microsecond)

 

12,5

Time of disruption lag, microsecond (with the speed of voltage increase on the electrodes of the surge absorber no less than 25 kV/microsecond)

 

0,5

Static interelectrode capacitance, picofarad

 

8

Dielectric resistance, Megaohm

100

 

Time of reduction of resistance of discharge gap, sec

 

0,5

Maintaining voltage, V

- with maximum plate current in the impulse

- stationary mode

 

 

150

50

Protective untriggered gap Ð-60 Protective untriggered gap Ð-60 Protective untriggered gap Ð-60

 

Instructions on the operation of protective untriggered gap Ð-60:

  • While operating protective untriggered gap Ð-60 parameter points shouldn't overrate the admissible values.
  • On-position of protective untriggered gap – any position.
  • Cooling down – natural cooling.
  • Protective untriggered gap Ð-60 is fixed in the device on the cathode flange with the help of 6 screws.

Top

 

 

 

 

 

 



 

 

 

Contact
information:

tel:
+7(4912) 45-62-58
 +7(4912) 21-06-13

fax:
 +7(4912) 28-20-89

more detail >>>



E-mail:
 vaccom@gmail.com


location map


 

 

 


Rambler's Top100

 

Copyright © 2000-2007 ÎÎÎ "Vacuum Components "
 