Protective untriggered gap Ð-59
Protective untriggered gap Ð-59 is designed to protect equipment from overwork in radio engineering facilities of movable and fixed equipment.
Basic electric parameters of protective untriggered gap Ð-59:
The name of the parameter, unit of measure |
Norm |
no less than |
no more than |
Puncture potential, static, V |
200 |
300 |
Puncture potential, dynamic, V (with the speed of voltage increase on the electrodes of the surge absorber no more than 5 kV/microsecond) |
. |
2500 |
Time of disruption lag, microsecond (with the speed of voltage increase on the electrodes of the surge absorber no more than 4 kV/microsecond) |
. |
0,5 |
Static interelectrode capacitance, picofarad |
. |
8 |
Dielectric resistance, Megaohm |
100 |
. |
Time of reduction of resistance of discharge gap, sec |
. |
0,5 |
Maintaining voltage, V
-
with maximum plate current in the impulse
-
stationary mode | .
. |
150
50
|
Instructions on the operation of protective untriggered gap Ð-59:
While operating protective untriggered gap Ð-59 parameter points shouldn't overrate the admissible values.
On-position of protective untriggered gap – any position.
Cooling down – natural cooling.
Protective untriggered gap Ð-59 is fixed in the device on the cathode flange with the help of 6 screws M6.
|