Protective untriggered gaps
Ð-125, Ð-134, P-135, P-136, P-137, P-138
Protective untriggered gaps Ð-125, Ð-134, Ð-135, Ð-136, Ð-137, Ð-138 are designed to protect the equipment of quasi-electronic and electronic systems of communication and other means of wire communication from external electrical action (thunderstorms, the interference induction of high-tension lines and the line-to-line with industrial network).
The version of protective untriggered gaps Ð-125-1, Ð-134-1, P-135-1, P-136-1, P-137-1, P-138-1 with flexible leads on demand.
Basic electric parameters of protective untriggered gaps Ð-125, Ð-134, Ð-135, Ð-136, Ð-137, Ð-138:
The name of the parameter, unit of measure |
Norm |
no less than |
no more than |
Puncture potential, static, V
Ð-125
P-134
P-135
P-136
P-137
P-138 |
210
60
72
88
116
255 |
260
90
108
132
174
345 |
Puncture potential, dynamic, V (with the speed of voltage increase of the anode = 1KV/microsecond)
P-134, P-135, P-136
Ð-125, P-137
P-138 |
|
600
700
900
|
Static interelectrode capacitance, picofarad, no more than |
|
2 |
Dielectric resistance, Ohm (with the temperature 20° relative humidity 75%), no less than |
10000 |
|
Extinguishing voltage, V (with maximum constant-current source 200 milliAmpere), no less than
P-134, P-135, P-136
Ð-125, P-137, P-138 |
50
90 |
|
Instructions on the operation of protective untriggered gaps Ð-125, Ð-134, P-135, P-136, P-137, P-138:
-
On-position of protective untriggered gap – any position.
-
Cooling down – natural cooling.
-
The binding in the device – in the special socket (or with the help of soldering).
-